- Manuals
- Brands
- ICP Manuals
- Furnace
- C9MPT050F12C1
- Technical support manual
Four position furnace
Hide thumbs
-
- Bookmarks
Advertisem*nt
Quick Links
- 1 Specifications
- Download this manual
Technical Support (*9MPT)
Circulation Air Blower Data (*9MPT)
Wiring Diagram (*9MPT)
Parts (*9MPT)
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Support (*9MPV)
Circulation Air Blower Data (*9MPV)
Wiring Diagram (*9MPV)
Parts (*9MPV)
. . . . . . . . . . . . . . . . . . . . . . . . . .
440 04 2023 02 August 2007
Four Position Furnace
. . . . . . . . . . . . . . . .
. . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . .
. . . . . . . . . . . . . . . . . .
Save This Manual For Future Reference
Models
Dual Certified
*9MPT050F12C1
*9MPT075F14C1
*9MPT100J16C1
*9MPT125L20C1
*9MPV050F12D1
*9MPV075F12D1
*9MPV100J20D1
*9MPV125L20D1
* Denotes Brand (C, H, T)
2
3
International Comfort Products, LLC
4
Lewisburg, TN 37091 U.S.A.
5
8
9
18
19
®
®
1
Table ofContents
Advertisem*nt
Related Manuals for ICP C9MPT050F12C1
-
Furnace ICP C9MPT User's Information Manual
Condensing gas furnaces 90+ four position furnaces; non-condensing gas furnaces 80+ four position furnaces (10 pages)
-
Furnace ICP C8MPL User's Information Manual
Condensing gas furnaces 95% upflow/horizontal, 90+ & 95% four position furnaces, non-condensing gas furnaces & 80+ four position furnaces (10 pages)
-
Furnace Icp N9MP1 Installation Instructions Manual
90+ single stage, category iv, furnance (59 pages)
-
Furnace ICP N9MP1 Service Manual
(60 pages)
-
Furnace ICP N8MPN Installation Instructions Manual
(57 pages)
-
Furnace ICP N8MPN Installation Instructions Manual
80% single stage, category i, gas furnace (44 pages)
-
Furnace Icp H9MPX Installation Insrtuctions
95+ single stage, category iv, condensing gas furnance (50 pages)
-
Furnace ICP C8DNL Installation Instructions Manual
80% single stage, downflow, category i, gas furnace (35 pages)
-
Furnace Icp H8MPT100J20A1 Installation Instructions Manual
Natural gas to propane and high altitude conversion kit (7 pages)
-
Furnace Icp H9MPT050F12B1 Installation Instructions Manual
Four position 2- stage condensing gas furnace (42 pages)
-
Furnace Icp H9MPT050F12B1 Installation Instructions Manual
90+2-stage& *9mpt & *9mpv variable speed (68 pages)
-
Furnace Icp H9MPT050F12B1 Installation Instructions Manual
90+2-stage &*9mpt & *9mpv variable speed (60 pages)
-
Furnace Icp H9UHX060F12A Installation Instructions Manual
90+ single stage gas furnace direct or nondirect vent category iv furnace (52 pages)
-
Furnace Icp T8DNL100F14B1 Installation Instructions Manual
80+ single stage, category i furnace (38 pages)
-
Furnace ICP 9MPD050F12B1 Installation Instructions Manual
90+ single stage category iv furnace fan assisted, direct vent gas furnace (63 pages)
-
Furnace ICP 8MPL075F16B1 Installation Instructions Manual
80+ single stage category i furnace (56 pages)
Summary of Contents for ICP C9MPT050F12C1
- Page 1 Four Position Furnace Models Dual Certified *9MPT050F12C1 *9MPT075F14C1 *9MPT100J16C1 *9MPT125L20C1 *9MPV050F12D1 *9MPV075F12D1 *9MPV100J20D1 *9MPV125L20D1 * Denotes Brand (C, H, T) ® ® Technical Support (*9MPT) ....Circulation Air Blower Data (*9MPT) .
-
Page 2: Specifications
TECHNICAL SUPPORT Manufacturers Number (Mfr No - -See Rating Plate) ALL Models Specifications *9MPT050F12 *9MPT075F14 *9MPT100J16 *9MPT125L20 General Gas Type Propane Propane Propane Propane Transformer Size (VA) T’stat Heat Anticipator Input (Btuh) Std/Alt. HI Heat 50,000 75,000 100,000 125,000 LO Heat 35,000 53,000 70,000... -
Page 3: Circulation Air Blower Data - *9Mpt
Circulation Air Blower Data - *9MPT *9MPT050F12 (1) * *9MPT100J16 (1) * Denotes Brand Denotes Brand Speed Speed Med L Med H Med L Med H 1083 1301 1408 1109 1527 1850 1050 1242 1347 1087 1482 1791 1028 1195 1295 1056 1426... -
Page 4: Wiring Diagram *9Mpt (Two Stage Heating With Psc Motor)
Wiring Diagram *9MPT (Two Stage Heating with PSC Motor) 440 04 2023 02 Specifications are subject to change without notice... - Page 5 *9MPT Parts 440 04 2023 02 Specifications are subject to change without notice...
- Page 6 Replacement Parts - *9MPT Models -- *9MPT050F12C1, *9MPT075F14C1, *9MPT100J16C1 & *9MPT125L20C1 (Natural Gas) Replacement part supplied will be current active part. For parts not listed, consult place of purchase. *9MPT *9MPT Description Part Description Part Functional Number Non- Functional Number Heat Exchanger, Primary 1012850 Panel, Top...
- Page 7 Replacement Parts - *9MPT Models -- *9MPT050F12C1, *9MPT075F14C1, *9MPT100J16C1 & *9MPT125L20C1 (Natural Gas) Replacement part supplied will be current active part. For parts not listed, consult place of purchase. *9MPT *9MPT Description Part Description Part Functional Number Functional Number Gasket, Attachment Plate 1012542 Trap, Drain Tee 1171916...
- Page 8 TECHNICAL SUPPORT Manufacturers Number (Mfr No - -See Rating Plate) ALL Models Specifications *9MPV050F12 *9MPV075F12 *9MPV100J20 *9MPV125L20 General Gas Type Propane Propane Propane Propane Transformer Size (VA) T’stat Heat Anticipator Input (Btuh) Std/Alt. HI Heat 50,000 75,000 100,000 125,000 LO Heat 35,000 52,500 70,000...
-
Page 9: Off Delay
Circulation Air Blower Data - *9MPV050 Cooling CFM Adjustment Heating Rise Adjustment Low Heat Low Cool ** Adjust High Heat DIP Switch High Cool @ DIP Switch Rise Change (80% of High Jumper Rise Change 5 & 6 0.50 in wc 3 &... - Page 10 Circulation Air Blower Data - *9MPV050 Cooling Airflow Settings High Cooling Airflows *9MPV050F12 1600 Legend Airflow Selection is 1400 from Highest to Lowest 00 (+) 1200 00 (NOM) 00 (-) 01 (+) 01 (NOM) 1000 01 (-) 10 (+) 10 (NOM) 10 (-) 11 (+) 11 (NOM)
- Page 11 Circulation Air Blower Data - *9MPV075 Cooling CFM Adjustment Heating Rise Adjustment Low Heat Low Cool ** Adjust High Heat DIP Switch High Cool @ DIP Switch Rise Change (80% of High Jumper Rise Change 5 & 6 0.50 in wc 3 &...
- Page 12 Circulation Air Blower Data - *9MPV075 Cooling Airflow Settings High Cooling Airflows *9MPV075F12 1800 Legend Airflow 1600 Selection is from Highest to Lowest 00 (+) 1400 00 (NOM) 01 (+) 1200 00 (-) 01 (NOM) 10 (+) 1000 01 (-) 10 (NOM) 11 (+) 10 (-)
- Page 13 Circulation Air Blower Data - *9MPV100 Cooling CFM Adjustment Heating Rise Adjustment Low Heat Low Cool ** Adjust High Heat DIP Switch High Cool @ DIP Switch Rise Change (80% of High Jumper Rise Change 5 & 6 0.50 in wc 3 &...
- Page 14 Circulation Air Blower Data - *9MPV100 Cooling Airflow Settings High Cooling Airflows *9MPV100J20 2700 Legend Airflow Selection is from Highest to Lowest 2200 00 (+) 00 (NOM) 00 (-) 01 (+) 1700 01 (NOM) 01 (-) 10 (+) 10 (NOM) 10 (-) 1200 11 (+)
- Page 15 Circulation Air Blower Data - *9MPV125 Cooling CFM Adjustment Heating Rise Adjustment Low Heat Low Cool ** Adjust High Heat DIP Switch High Cool @ DIP Switch Rise Change (80% of High Jumper Rise Change 5 & 6 0.50 in wc 3 &...
- Page 16 Circulation Air Blower Data - *9MPV125 Cooling Airflow Settings High Cooling Airflows *9MPV125L20 2700 Legend Airflow Selection is from Highest to Lowest 2200 00 (+) 00 (NOM) 00 (-) 01 (+) 1700 01 (NOM) 01 (-) 10 (+) 10 (NOM) 10 (-) 1200 11 (+)
- Page 17 Variable Speed (MPV) Tap Select Interface Board (TSIB) TO FURNACE BOARD + NOM BLOWER ADJUST TO FURNACE CONTROL 24VAC + NOM BLOWER ADJUST AC/HP EFFICIENCY INCREASE/NO CHANGE/DECREASE HP COMFORT SELECTION HP MODE SELECT 1 2 3 4 FROM 24V TRANS RED CONT COOL HEAT...
- Page 18 Wiring Diagram *9MPV (Variable Speed Blower Motor) Specifications are subject to change without notice 440 04 2023 02...
- Page 19 *9MPV Parts 440 04 2023 02 Specifications are subject to change without notice...
- Page 20 Replacement Parts - *9MPV Models -- *9MPV050F12D1, *9MPV075F12D1, *9MPV100J20D1 & *9MPV125L20D1 (Natural Gas) Replacement part supplied will be current active part. For parts not listed, consult place of purchase. *9MPV *9MPV Description Part Part Description Functional Number Number Heat Exchanger, Primary 1012850 Panel, Top 1012866...
- Page 21 Replacement Parts - *9MPV Models -- *9MPV050F12D1, *9MPV075F12D1, *9MPV100J20D1 & *9MPV125L20D1 (Natural Gas) Replacement part supplied will be current active part. For parts not listed, consult place of purchase. *9MPV *9MPV Part Part Description Description Number Number PART NOT ILLUSTRATED Partition, Front Ht Exchger 1012650 Door Screws...
This manual is also suitable for:
C9mpt075f14c1C9mpt100j16c1C9mpt125l20c1Cmpv050f12d1C9mpv075f12d1C9mpv100j20d1 ... Show all